Kubota GL11000TM 11000 Watt Lowboy II Series Industrial Diesel Generator w Output Terminals Discount
- Estimated Delivery : Up to 4 business days
- Free Shipping & Returns : On all orders over $200
Kubota GL11000TM – 11,000 Watt Lowboy II Series Industrial Diesel Generator w Output Terminals
The Kubota LOWBOY II Model GL11000 USA Series is designed to have the minimum possible height while using vertical diesel engines. This is achieved by direct coupling of the engine crankshaft with the cooling fan. Since they require less space for operation, the range of possible applications has been greatly increased. This genset has a very small foot print of 51 x 24.3 x 27.5 inches.
Add an automatic start module and this is ready for a commercial or residential back up or an off the grid primary power source. Units are not weather proof.
This model features a premium Kubota model D722, 3 cylinder, 18.9 HP, diesel fueled, liquid cooled engine with electric start. This model runs at 3600 RPM and generates 11 kW (11 kVA) 60 Hz,of Standby (emergency or maximum) power and 9.9 kW prime (continuous) power at a primary voltage of 120 240 VAC, single phase, 60 Hertz, with voltage accuracy.
Enclosed weight is 650 lbs. Shipping weight 690 lbs. Shipping dimensions 52 W x 25 L x 31 H. Enclosed quietness is 68 db at 7 meter
FEATURES
Kubota Low Boy II Industrial Diesel Generator
- Quieter, more compact & cleaner (EPA Tier II) than original Low Boy
-
479cc Kubota Z482 Liquid-Cooled Diesel Engine
- Large capacity oil pan provides oil change intervals up to 200 hours
-
Dual-element air filter design for heavy-duty jobs in dusty conditions
- Keyed Electric Start (Battery Included)
-
Starter safety relay prevent starter from engaging after start-up
- Compact Design & Easy Maintenance
-
By direct coupling the engine crankshaft w cooling fan
- Simple maintenance of oil, fuel, battery & cooling water on One side
-
Large Capacity 7.4 Gallon Diesel Fuel Tank
- Provides up to 10 hours @ 100% load on a single fill-up
-
Monitor Gauges & Automatic Safety Shutdowns
- Easily see when there’s water temperature & oil pressure issues
-
Double Circuit Breaker Protection (Generator & Receptacle)
- Shuts the engine down to prevent overcurrent damage
-
Less Noise During Operation (66 dB(A) @ 23′)
- Slower-speed fan, built-in muffler & reduced air intake sound
-
Plus Forklift pockets, One-Point Lifting Eye & ATS Terminal 1-Year Limited Warranty
SPECIFICATIONS
MODEL
Unit
GL11000
Type
–
Rotating field single-phase AC generator
Frequency
Hz
60
Standby Output
kVA (kW)
11.0 (11.0)
Prime Output
kVA (kW)
10.0 (10.0)
Voltage – Single Phase
V
120 240
Armature Connection
–
Series
Phase Wire
–
1 3
Power Factor
–
1.0
No. of Poles
–
2
Insulation
Class
Rotor coil; class F, Stator coil; class B
Type of Coupling
–
Direct coupled
AMPS
Single Phase 120V
A
83.3
Single Phase 240V
A
41.7
5-15R (GFCI)
–
N A
5-20RA (GFCI)
–
2
6-15R
–
N A
L5-30R
–
1
L6-30R
–
1
CS-6369
–
1
TERMINAL
Terminal
–
Available
DIESEL ENGINE
Type
–
Vertical, liquid-cooled,
4-cycle diesel engine
Model
–
D722
No. of Cylinders
–
3
Bore x Stroke
mm (in.)
67.0 x 68.0 (2.6 x 2.7)
Displacement
L (cu. in.)
0.719 (43.9)
Engine Speed
rpm
3600
Continuous Rated Output
kW (HP)
12.2 (16.3)
Lubricant
(API classification)
–
Above CD grade
Oil Capacity
L (qts.)
3.4 (0.9)
Coolant Capacity
L (qts.)
4.1 (1.1)
Starting System
–
Electric – 12 volt DC
SET
Fuel
–
Diesel fuel No.2
(ASTM D975)
Fuel
Consumption
at Full Load
L h (gal. h)
4.1 (1.09)
at 3 4 Load
L h (gal. h)
3.3 (0.86)
at 1 2 Load
L h (gal. h)
2.7 (0.71)
at 1 4 Load
L h (gal. h)
2.2 (0.59)
Fuel Tank Capacity
L (gal.)
28.0 (7.4)
Continous
Operation
Hours
at Full Load
h
7.0
at 3 4 Load
h
8.5
at 1 2 Load
h
10.4
at 1 4 Load
h
12.7
Battery (Ah 5h)
–
55B24R (12V x 36Ah)
Dimensions
L x W x H
mm
(in.)
1281 x 618 x 698
(50.4 x 24.3 x 27.5)
Approx. Net Weight
kg (lbs.)
295 (650)
Sound Level
(Full Load at 23 ft. [7m])
dB (A)
68
Emergency Stop System
–
In case of abnormal: oil pressure, water temperature, or when the access terminal cover is opened (terminal type only)
Note regarding oil fill level at oil change: Here’s the update from Kubota Engines. The 722 generator on the GL11000 comes with either a 101mm or a 120mm deep oil pan. (4” or 4.75”). The 101 takes .9 gallons of oil. The 120 takes 1 gallon. If the unit has the 4.75” deep oil pan it requires 1 gallon to fill it to the top mark on the dipstick. The GL11000-USA uses dip stick part #1G304-36410.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
For the first 2 years or 2000 hours you must use factory filters, or you will void warranty. The owner’s manual recommends you change oil and oil filter first 50 hours. After that change the oil every 100 hours and the oil filter every 200 hours. Suggestion: I like to use Mobil ® Delvac 1300 Super Diesel Motor oil for the engine oil and oil changes. Do not use automotive grade oil.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
Size
Generator, Generator + Remote panel with Auto start and a 20 foot harness
Review Cart
Kubota Low Boy II Industrial Diesel Generator
- Quieter, more compact & cleaner (EPA Tier II) than original Low Boy
- Large capacity oil pan provides oil change intervals up to 200 hours
- Keyed Electric Start (Battery Included)
-
- Compact Design & Easy Maintenance
-
- Simple maintenance of oil, fuel, battery & cooling water on One side
- Provides up to 10 hours @ 100% load on a single fill-up
- Easily see when there’s water temperature & oil pressure issues
- Shuts the engine down to prevent overcurrent damage
- Slower-speed fan, built-in muffler & reduced air intake sound
Plus Forklift pockets, One-Point Lifting Eye & ATS Terminal 1-Year Limited Warranty
SPECIFICATIONS
MODEL Unit GL11000 Type – Rotating field single-phase AC generator Frequency Hz 60 Standby Output kVA (kW) 11.0 (11.0) Prime Output kVA (kW) 10.0 (10.0) Voltage – Single Phase V 120 240 Armature Connection – Series Phase Wire – 1 3 Power Factor – 1.0 No. of Poles – 2 Insulation Class Rotor coil; class F, Stator coil; class B Type of Coupling – Direct coupled AMPS Single Phase 120V A 83.3 Single Phase 240V A 41.7 5-15R (GFCI) – N A 5-20RA (GFCI) – 2 6-15R – N A L5-30R – 1 L6-30R – 1 CS-6369 – 1 TERMINAL Terminal – Available DIESEL ENGINE Type – Vertical, liquid-cooled,
4-cycle diesel engineModel – D722 No. of Cylinders – 3 Bore x Stroke mm (in.) 67.0 x 68.0 (2.6 x 2.7) Displacement L (cu. in.) 0.719 (43.9) Engine Speed rpm 3600 Continuous Rated Output kW (HP) 12.2 (16.3) Lubricant
(API classification)– Above CD grade Oil Capacity L (qts.) 3.4 (0.9) Coolant Capacity L (qts.) 4.1 (1.1) Starting System – Electric – 12 volt DC SET Fuel – Diesel fuel No.2
(ASTM D975)Fuel
Consumptionat Full Load L h (gal. h) 4.1 (1.09) at 3 4 Load L h (gal. h) 3.3 (0.86) at 1 2 Load L h (gal. h) 2.7 (0.71) at 1 4 Load L h (gal. h) 2.2 (0.59) Fuel Tank Capacity L (gal.) 28.0 (7.4) Continous
Operation
Hoursat Full Load h 7.0 at 3 4 Load h 8.5 at 1 2 Load h 10.4 at 1 4 Load h 12.7 Battery (Ah 5h) – 55B24R (12V x 36Ah) Dimensions
L x W x Hmm
(in.)1281 x 618 x 698
(50.4 x 24.3 x 27.5)Approx. Net Weight kg (lbs.) 295 (650) Sound Level
(Full Load at 23 ft. [7m])dB (A) 68 Emergency Stop System – In case of abnormal: oil pressure, water temperature, or when the access terminal cover is opened (terminal type only) Note regarding oil fill level at oil change: Here’s the update from Kubota Engines. The 722 generator on the GL11000 comes with either a 101mm or a 120mm deep oil pan. (4” or 4.75”). The 101 takes .9 gallons of oil. The 120 takes 1 gallon. If the unit has the 4.75” deep oil pan it requires 1 gallon to fill it to the top mark on the dipstick. The GL11000-USA uses dip stick part #1G304-36410.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
For the first 2 years or 2000 hours you must use factory filters, or you will void warranty. The owner’s manual recommends you change oil and oil filter first 50 hours. After that change the oil every 100 hours and the oil filter every 200 hours. Suggestion: I like to use Mobil ® Delvac 1300 Super Diesel Motor oil for the engine oil and oil changes. Do not use automotive grade oil.
KUBOTA FILTERS for GL 4500, GL 6500, GL 7000, GL 11000 AND GL14000 Watt Diesel Generators
Size Generator, Generator + Remote panel with Auto start and a 20 foot harness
Review Cart
Less Noise During Operation (66 dB(A) @ 23′)
Double Circuit Breaker Protection (Generator & Receptacle)
Monitor Gauges & Automatic Safety Shutdowns
Large Capacity 7.4 Gallon Diesel Fuel Tank
By direct coupling the engine crankshaft w cooling fan
- Simple maintenance of oil, fuel, battery & cooling water on One side
Starter safety relay prevent starter from engaging after start-up
Dual-element air filter design for heavy-duty jobs in dusty conditions
479cc Kubota Z482 Liquid-Cooled Diesel Engine